Grounding & Leakage Current

Grounding installations, residual-current protection, measurement reports. Code-compliant safety backed by certified measurement.

What is Grounding & Leakage Current Protection?

Proper grounding and residual-current protection are the foundation of electrical safety. They protect personnel from electric shock, prevent equipment damage during faults, and are mandatory under Turkish electrical regulations.

Our Service Scope

We deliver grounding system design for industrial and residential, certified measurement reports, RCD (kaçak akım) installation, equipotential bonding, and lightning protection coordination.

Our Service Scope

Grounding Installation

Foundation rebar bonding, copper rod electrodes, mesh grids, soil resistivity surveys.

Measurement & Reporting

Certified earth-resistance measurements with calibrated equipment; reports valid for insurance/audit.

RCD Selection & Install

Type AC, A, B and F selection per load; selectivity coordination across panels.

Equipotential & Lightning

EBB installation, lightning protection coordination, surge protection (SPD) device sizing.

Benefits We Deliver

  • Personnel safety against electric shock
  • Equipment protection during faults — fewer insurance claims
  • Code compliance for residential, commercial and industrial
  • Documented measurement reports for audit
  • Lightning + surge protection for sensitive electronics

Who We Serve

Industrial plants, commercial buildings, residential estates, schools, hospitals, data centers, telecom sites, agricultural facilities and any installation requiring certified grounding.

📞 Call Me Back

Leave your number, we'll call you as soon as possible.

Urgent? Call directly: +90 535 729 49 25

FAQ

Frequently Asked Questions

How often should grounding be measured?

Annually for industrial and commercial installations; every 2 years for residential. Insurance and audit may require more frequent measurement.

Type A or Type B RCD?

Type A for general residential/commercial; Type B mandatory for installations with VFD drives, EV chargers, solar inverters or DC-load equipment.

Can old buildings be retrofitted with proper grounding?

Yes. We retrofit grounding via foundation bonding (where accessible) or external rod arrays. Equipotential bonding can always be added.